22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable

Product Details
Customization: Available
Application: Construction, Overhead, Industrial, Power Station, Telecommunication
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of US$ 1/Meter
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 7 foreign trading staff(s) and 7 staff(s) with over 6 years of overseas trading experience
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (15)
  • 22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable
  • 22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable
  • 22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable
  • 22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable
  • 22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable
  • 22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable
Find Similar Products

Basic Info.

Model NO.
Medium Voltage Power Cable
Current
DC & AC
Insulation Material
XLPE
Sheath Material
PVC/XLPE/PE/LSZH/CPE
Material Shape
Round Wire
Wire Core Material
Copper or Aluminum
Certification
ISO, CCC, CE, RoHS
Model
YJLV22
Brand
Henway
Quality
High Quality
Standard
ASTM, BS, as, DIN, CSA, IEC, GB/T
Cores
1core or 3cores
Transport Package
Wooden Drums, Steel-Wooden Drums, Steel Drums
Trademark
Henway
Origin
China
HS Code
7614900000
Production Capacity
10, 000, 000km Per Year

Product Description

5KV to 46KV Medium Voltage Cable
Application: Medium voltage power cables are apply for power transmission and distribution line at AC rated voltage up to 46kV.
Applicable standards: IEC60502-2, BS6622, SANS1339, AS/NZS1429.1, DIN VDE 0276-626,  NFC 33-226, IEC60840, ICEA S-93-639,ICEA S-94-649, HD620,CSA C68.10or the standards agreed by both of the customers and us.  
Construction:
Conductor: IEC60228 class 1 class 2  bear copper/Aluminum etc
Conductor Screen: Semi-conducting compound
Insulation:  XLPE or EPR
Insulation Screen: Semi-conducting compound
Core:  1core or 3cores
Shield: Copper wire/ Copper tape/AL plastic tape/Aluminum tape
Inner Sheath( optional): PVC PE LSZH  CPE
Armoured ( optional): Galvanized steel wire/Aluminum wire/Two layers of Aluminum tapegap-wrapped /Two layers of steel tape gap-wrapped / Galvanized steel interlocked armour/Aluminum alloy interlocked armour
Outer Sheath: PVC PE LSZH CPE
 
3.6/6KV XLPE  Insulated aluminum wire armour PVC sheath  power cable
Number of Cores and Nominal Area Thickness of Insulation Approx. Overall Diameter Approx mass Max. DC Resistance
at 20
ºC
Current Rating
Copper Aluminium
Copper Aluminium Copper Aluminium Direct In Soil In air Direct In Soil In air
Nos×mm2 mm mm kg/km kg/km Ohm/km Ohm/km A A A A
1×25 2.5 23.8 866 715 0.727 1.20 140 163 108 127
1×35 2.5 24.9 993 784 0.524 0.868  166 198 129 154
1×50 2.5 26.0 1152 867 0.387 0.641  196 238 152 184
1×70 2.5 27.7 1407 994 0.268 0.443  239 296 186 230
1×95 2.5 29.6 1721 1152 0.193 0.320  285 361 221 280
1×120 2.5 31.1 1994 1275 0.153 0.253  323 417 252 324
1×150 2.5 32.7 2301 1425 0.124 0.206  361 473 281 368
1×185 2.5 35.4 2804 1696 0.0991 0.164  406 543 317 424
1×240 2.6 38.0 3430 1976 0.0754 0.125  469 641 367 502
1×300 2.8 40.8 4119 2294 0.0601 0.100  526 735 414 577
1×400 3.0 44.4 5043 2706 0.0470 0.0778  590 845 470 673
1×500 3.2 49.8 6393 3398 0.0366 0.0605  735 958 578 767
1×630 3.2 53.9 7892 4024 0.0283 0.0469 831 1098 665 896
1×800 3.2 58.2 9719 4757 0.0221 0.0367 945 1266 761 1041
Trefoil arrangement;Maximum conductor temperature 90 °C ;Ambient air temperature 30 °C ;Ground temperature 20 °C ;Depth of laying 0,8 m ;
Thermal resistivity of soil 1,5 K.m/W
3.6/6KV XLPE  Insulated steel wire armour PVC sheath power cable
Number of Cores and Nominal Area Nominal Thickness of Insulation Approx. Overall Diameter Approx mass Max. DC Resistance
at 20
ºC
Current Rating
Copper Aluminium
Copper Aluminium Copper Aluminium Direct In Soil In air Direct In Soil In air
Nos×mm2 mm mm kg/km kg/km Ohm/km Ohm/km A A A A
3×25 2.5 41.9 3207 2748 0.727 1.20 129 143 100 111
3×35 2.5 45.6 4054 3430 0.524 0.868  154 172 119 133
3×50 2.5 48.2 4654 3792 0.387 0.641  181 205 140 159
3×70 2.5 52.2 5592 4347 0.268 0.443  220 253 171 196
3×95 2.5 56.1 6703 4975 0.193 0.320  263 307 204 238
3×120 2.5 60.0 7762 5582 0.153 0.253  298 352 232 274
3×150 2.5 63.4 8878 6187 0.124 0.206  332 397 259 309
3×185 2.5 67.3 10248 6881 0.0991 0.164  374 453 293 354
3×240 2.6 73.5 12509 8072 0.0754 0.125  431 529 338 415
3×300 2.8 81.0 15741 10190 0.0601 0.100  482 599 380 472
3×400 3.0 88.8 19093 11996 0.0470 0.0778  541 683 432 545
Trefoil arrangement;Maximum conductor temperature 90 °C ;Ambient air temperature 30 °C ;Ground temperature 20 °C ;Depth of laying 0,8 m ;
Thermal resistivity of soil 1,5 K.m/W
18/30KV XLPE  Insulated aluminum wire armour PVC sheath power cable
Number of Cores and Nominal Area Thickness of Insulation Approx. Overall Diameter Approx mass Max. DC Resistance
at 20
ºC
Current Rating
Copper Aluminium
Copper Aluminium Copper Aluminium Direct In Soil In air Direct In Soil In air
Nos×mm2 mm mm kg/km kg/km Ohm/km Ohm/km A A A A
1×35 8.0 37.4  1840 1630 0.524 0.868  170 201 132 158
1×50 8.0 38.7  2036 1751 0.387 0.641  200 242 156 190
1×70 8.0 40.4  2335 1920 0.268 0.443  242 300 190 235
1×95 8.0 42.3  2681 2112 0.193 0.320  288 363 224 285
1×120 8.0 43.8  2996 2278 0.153 0.253  326 420 256 328
1×150 8.0 46.4  3506 2621 0.124 0.206  364 476 286 372
1×185 8.0 48.3  3970 2862 0.0991 0.164  409 546 321 428
1×240 8.0 50.9  4661 3207 0.0754 0.125  472 645 372 505
1×300 8.0 53.5  5380 3555 0.0601 0.100  529 740 418 578
1×400 8.0 56.7  6333 3996 0.0470 0.0778  593 848 475 675
1×500 8.0 60.5  7556 4561 0.0366 0.0605  740 963 583 772
1×630 8.0 64.8  9172 5304 0.0283 0.0469 835 1101 675 900
1×800 8.0 69.1  11063 6101 0.0221 0.0367 950 1272 765 1046
Trefoil arrangement;Maximum conductor temperature 90 °C ;Ambient air temperature 30 °C ;Ground temperature 20 °C ;Depth of laying 0,8 m ;
Thermal resistivity of soil 1,5 K.m/W
                     
18/30KV XLPE  Insulated steel wire armour PVC sheath power cable
Number of Cores and Nominal Area Thickness of Insulation Approx. Overall Diameter Approx mass Max. DC Resistance
at 20
ºC
Current Rating
Copper Aluminium
Copper Aluminium Copper Aluminium Direct In Soil In air Direct In Soil In air
Nos×mm2 mm mm kg/km kg/km Ohm/km Ohm/km A A A A
3×35 8.0 72.1 7473 6848 0.524 0.868  154 175 118 132
3×50 8.0 76.2 9011 8149 0.387 0.641  180 210 139 158
3×70 8.0 80.3 10196 8951 0.268 0.443  217 258 171 200
3×95 8.0 84.4 11479 9751 0.193 0.320  261 310 204 240
3×120 8.0 88.0 12743 10563 0.153 0.253  296 353 229 279
3×150 8.0 91.2 13918 11228 0.124 0.206  332 405 256 310
3×185 8.0 95.3 15562 12196 0.0991 0.164  374 458 293 360
3×240 8.0 101.1 18038 13601 0.0754 0.125  429 535 338 420
3×300 8.0 106.2 20502 14952 0.0601 0.100  482 602 380 474
3×400 8.0 113.0 23898 16800 0.0470 0.0778  541 690 428 545
Trefoil arrangement;Maximum conductor temperature 90 °C ;Ambient air temperature 30 °C ;Ground temperature 20 °C ;Depth of laying 0,8 m ;
Thermal resistivity of soil 1,5 K.m/W

Products Pictures
22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable
Packing and loading containers pictures:
22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable
* We can design and produce ACSR according to client's requirement. Any requirement, feel free to contact us!

Company Information

22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable

Certification

22kv 11kv Medium Voltage Cu XLPE PVC Swa Armored Underground Power Cable

FAQ


1. Q:How does your factory control the quality?

A:Factory has a quick and enthusiastic merchandisers team, strict and responsible QC team, service for many well-known brands all around the world with our high-quality products and strict.

2. Q:Can I visit your company?

A: Sure,If you need,we will arrange the driver to pick you up.

3. Q:How can I get some samples?

A: Contact me on below,Determin sample and address for shipping.

4. Q:Have you ever supplied cables to our country?

A:  Henway Cables have been sold to over 100 countries and regions in the world. you can contact me for details.

5. Q:What is your MOQ?

A: MOQ Normally 500 meters for big diameter cables. Please contact me for detail info if you have specific cable requirement.

6.  Q:When can I get the price?

A: Usually quote within 6 hours after we get your inquiry.

7. Q:How long is your delivery time?

A: According to your order's quantity. Usually our lead time is 3 - 20 working days.
 

For more information about wires and cables, please feel free to contact us. Your inquiries will be replied to within 6 hours!!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier