Customization: | Available |
---|---|
Application: | Construction, Overhead, Industrial, Power Station, Telecommunication |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 1/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Number of Cores x Nominal Cross Section,No.x mm2 | Nominal Thickness of Insulation mm | Approx Overall Diameter mm |
Approx. mass Kg/Km |
Maximum Conductor Resistance Ω/Km |
Minimum Breaking Load,KN | Current Rating A |
||
Phase core | Neutral core | Lighting core | ||||||
2×16 | 1.2 | 1.2 | - | 15 | 130 | 1.91 | 2.3 | 93 |
2×16 + 2×1.5 | 1.2 | 1.2 | - | 16 | 175 | 1.91 / 12.1 | ||
4×16 | 1.2 | 1.2 | - | 18 | 260 | 1.91 | 83 | |
4×16 + 2×1.5 | 1.2 | 1.2 | - | 20 | 310 | 1.91 / 12.1 | ||
2×25 | 1.4 | 1.4 | - | 18 | 202 | 1.2 | 3.8 | 122 |
2×25 + 2×1.5 | 1.4 | 1.4 | - | 19.5 | 250 | 1.2 / 12.1 | ||
4×25 | 1.4 | 1.4 | - | 22 | 404 | 1.2 | 111 | |
4×25 + 2×1.5 | 1.4 | 1.4 | - | 24 | 452 | 1.2/ 12.1 | ||
3×35 +1×54.6 + K×16 (K can be 0,1,2,3) |
1.6 | 1.6 | 1.2 | 28.5/29.5/31/33 | 620/685/750/815 | 0.868/0.63/1.91 | 16.6 | 138/83 |
3×50 +1×54.6 + K×16 (K can be 0,1,2,3) |
1.6 | 1.6 | 1.2 | 30.5/32.5/34/36 | 740/805/870/935 | 0.641/0.63/1.91 | 165/83 | |
3×70 +1×54.6 + K×16 (K can be 0,1,2,3) |
1.8 | 1.6 | 1.2 | 34.5/36/39/41 | 975/1040/1105/1170 | 0.868/0.63/1.91 | 213/83 | |
3×95 +1×70+K×16 (K can be 0,1,2,3) |
1.8 | 1.5 | 1.2 | 37/39.5/42/44 | 1210/1275/1340/1405 | 0.32/0.50/1.91 | 20.5 | 258/83 |
3×120 +1×70+K×16 (K can be 0,1,2,3) |
1.8 | 1.5 | 1.2 | 38.5/40.5/43.5/46 | 1477/1542/1607/1672 | 0.253/0.50/1.91 | 300/83 | |
3×120 +1×95+K×16 (K can be 0,1,2,3) |
1.8 | 1.6 | 1.2 | 39.5/41.5/44.5/47 | 1535/1600/1665/1730 | 0.253/0.343/1.91 | 27.5 | |
3×150 +1×70+K×16 (K can be 0,1,2,3) |
1.7 | 1.5 | 1.2 | 40.5/42/44.5/48 | 1755/1820/1885/1950 | 0.206/0.50/1.91 | 20.5 | 344/83 |
3×150 +1×95+K×16 (K can be 0,1,2,3) |
1.7 | 1.6 | 1.2 | 43.2/45.3/47/49 | 1832/1897/1961/2026 | 0.206/0.343/1.91 | 27.5 |
Item# | Phase Conductor | Phase Conductor Insulation | Bare Neutral Messenger Size AWG | Bare Neutral Messenger Breaking Strength | Weight Per 1000ft-XLPE | Weight Per 1000ft-PE | Ampacity-XLPE A |
Ampacity-PE A |
Bay | 6 | 45mls | 6 | 1110Lbs | 145Lbs | 140.0 Lbs | 75 | 60 |
French coach | 6 | 45mls | 6 | 155Lbs | 144.3 Lbs | |||
German Coach | 4 | 45mls | 4 | 1760Lbs | 214Lbs | 208.3 Lbs | 100 | 80 |
Arabian | 4 | 45mls | 4 | 229 Lbs | 214.4 Lbs | |||
Belgian | 2 | 45mls | 2 | 2800Lbs | 344 Lbs | 323.1 Lbs | 135 | 105 |
Shetland | 1/0 | 60mls | 1/0 | 4460Lbs | 546 Lbs | 521.1 Lbs | 180 | 140 |
Thoroughbred | 2/0 | 60mls | 2/0 | 5390Lbs | 670 Lbs | 641.5 Lbs | 205 | 160 |
Trotter | 3/0 | 60mls | 3/0 | 6790Lbs | 825 Lbs | 791.8 Lbs | 235 | 185 |
Walking | 4/0 | 60mls | 4/0 | 8560Lbs | 1019 Lbs | 979.7 Lbs | 275 | 210 |
For more information about wires and cables, please feel free to contact us. Your inquiries will be replied to within 6 hours!!