Bare Aluminum Conductor Alloy Reinforced (ACAR) Cable

Product Details
Customization: Available
Application: Construction, Overhead, Industrial, Power Station, Telecommunication
Voltage: Low Voltage to High Voltage
Still deciding? Get samples of US$ 1/Meter
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 7 foreign trading staff(s) and 7 staff(s) with over 6 years of overseas trading experience
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (15)
  • Bare Aluminum Conductor Alloy Reinforced (ACAR) Cable
  • Bare Aluminum Conductor Alloy Reinforced (ACAR) Cable
Find Similar Products

Basic Info.

Current
DC & AC
Insulation Material
Bare
Sheath Material
Bare
Material Shape
Round Wire
Wire Core Material
Acar
Certification
ISO, CCC, CE, RoHS
Model
Acar
Brand
Henway
Quality
High Quality
Standard
ASTM B230, ASTM B398, ASTM B524
Construction
Concentric Stranded
Conductor Material
Aluminum with Alloy
Transport Package
Wooden Drums, Steel-Wooden Drums, Steel Drums
Specification
16mm2 to 1500mm2
Trademark
Henway
Origin
China
HS Code
7614900000
Production Capacity
10, 000, 000km Per Year

Product Description

Bare Aluminum Conductor Alloy Reinforced (ACAR) Cable

Application:  
Aluminum Conductor Alloy Reinforced (ACAR) cable is an excellent conductor choice where current carrying capacity, higher strength and a lower conductor weight are critical to the line design.

Applicable Standards:
ASTM B230 Specification for Aluminum 1350-H19 Wire for Electrical Purposes
ASTM B398 Specification for Aluminum Alloy 6201-T81 Wire for Electrical Purposes
ASTM B524 Specification for Concentric-Lay-Stranded Aluminum Conductors, Aluminum Alloy Reinforced (ACAR, 1350/6201)

Production Scope:
Max. Cross-section 3000MCM, Max. stranded number 91Nos.
We can according to our client's need and also provide technical data.

Construction:
Aluminum Conductor Alloy Reinforced (ACAR) cable has aluminum 1350 H-19 wires stranded around a 6201-T81 aluminum alloy core concentrically


ASTM B-230/B-398/B-524 standard:
Total Cross
Selection
Overall
Diameter
Stranding- Number and Diameter Mass Rated
Strength
20ºC DC Resistance
Outer Strands-EC-H19
Diameter
Reinforced Strands-6201-T81
kcmil or AWG  mm2  mm  No.  mm No.  mm  kg/km  kN Ω/km
30.6 15.48 5.029 4 1.68 3 1.68 42.7 3.67 2.0204
 #4 AWG   21.16 5.893 4 1.96 3 1.96 58.3 4.98 1.4811
48.7 24.65 6.35 4 2.12 3 2.12 68 6.63 1.2697
 #2 AWG   33.61 7.417 4 2.47 3 2.47 92.7 8.99 0.9306
77.5 39.23 8.026 4 2.67 3 2.67 108.2 10.32 0.7978
 #1/0 AWG   53.48 9.347 4 3.12 3 3.12 147.5 11.97 0.5855
123.3 62.45 10.109 4 3.37 3 3.37 172.2 13.97 0.5012
 #2/0 AWG   67.42 10.516 4 3.50 3 3.50 185.9 14.72 0.4642
155.4 78.77 11.354 4 3.79 3 3.79 217.1 17.04 0.3976
 #3/0 AWG   84.97 11.786 4 3.93 3 3.93 234.4 18.24 0.3684
195.7 99.16 12.751 4 4.25 3 4.25 273.4 21.31 0.3158
 #4/0 AWG   107.29 13.259 4 4.42 3 4.42 295.5 23.04 0.2919
246.9 125.1 14.3 4 4.77 3 4.77 345 26.87 0.2503
250 126.64 14.58 15 2.91 4 2.91 349.3 24.38 0.2395
250 126.64 14.58 12 2.91 7 2.91 349.3 27.58 0.2451
300 152.13 15.977 15 3.19 4 3.19 419.2 28.91 0.1993
300 152.13 15.977 12 3.19 7 3.19 419.2 32.83 0.2040
350 177.29 17.247 15 3.45 4 3.45 489 33.23 0.1710
350 177.29 17.247 12 3.45 7 3.45 489 37.41 0.1750
400 202.71 18.44 15 3.69 4 3.69 558.8 37.5 0.1496
400 202.71 18.44 12 3.69 7 3.69 558.8 42.35 0.1531
450 228 79.558 15 3.91 4 3.91 628.6 41.59 0.1330
450 228 19.558 12 3.91 7 3.91 628.6 47.15 0.1361
500 253.29 20.599 15 4.12 4 4.12 698.5 46.26 0.1197
500 253.29 20.599 12 4.12 7 4.12 698.5 52.49 0.1225
500 253.16 20.65 33 2.95 4 2.95 698.5 44.48 0.1181
500 253.16 20.65 30 2.95 7 2.95 698.5 48.04 0.1195
500 253.16 20.65 24 2.95 13 2.95 698.5 52.93 0.1223
500 253.16 20.65 18 2.95 19 2.95 698.5 58.72 0.1253
550 278.58 21.615 15 4.32 4 4.32 768.3 50.71 0.1088
550 278.58 21.615 12 4.32 7 4.32 768.3 57.83 0.1114
550 278.71 21.666 33 3.10 4 3.10 768.3 48.04 0.1073
550 278.71 21.666 30 3.10 7 3.10 768.3 52.04 0.1085
550 278.71 21.666 24 3.10 13 3.10 768.3 57.38 0.1111
550 278.71 21.666 18 3.10 19 3.10 768.3 64.05 0.1138
Total Cross
Selection
Overall
Diameter
Stranding- Number and Diameter Mass Rated
Strength
20ºC DC Resistance
Outer Strands-EC-H19
Diameter
Reinforced Strands-6201-T81
kcmil or AWG   mm2    mm   No.   mm  No.  mm   kg/km    kN  Ω/km
600 304 22.581 15 4.51 4 4.51 838.1 55.6 0.0997
600 304 22.581 12 4.51 7 4.51 838.1 62.72 0.1021
600 303.81 22.631 33 3.23 4 3.23 838.1 52.49 0.0984
600 303.81 22.631 30 3.23 7 3.23 838.1 56.94 0.0995
600 303.81 22.631 24 3.23 13 3.23 838.1 62.72 0.1019
600 303.81 22.631 18 3.23 19 3.23 838.1 70.28 0.1044
650 329.16 23.571 33 3.37 4 3.37 908.1 56.94 0.0908
650 329.16 23.571 30 3.37 7 3.37 908.1 61.39 0.0918
650 329.16 23.571 24 3.37 13 3.37 908.1 68.06 0.0940
650 329.16 23.571 18 3.37 19 3.37 908.1 76.06 0.0963
700 354.45 24.46 33 3.49 4 3.49 977.9 60.5 0.0843
700 354.45 24.46 30 3.49 7 3.49 977.9 65.39 0.0853
700 354.45 24.46 24 3.49 13 3.49 977.9 71.62 0.0873
700 354.45 24.46 18 3.49 19 3.49 977.9 79.62 0.0894
750 380.13 25.324 33 3.62 4 3.62 1047.7 64.05 0.0786
750 380.13 25.324 30 3.62 7 3.62 1047.7 69.39 0.0795
750 380.13 25.324 24 3.62 13 3.62 1047.7 76.06 0.0814
750 380.13 25.324 18 3.62 19 3.62 1047.7 84.52 0.0834
800 405.16 26.137 33 3.73 4 3.73 1117.6 68.06 0.0738
800 405.16 26.137 30 3.73 7 3.73 1117.6 73.84 0.0746
800 405.16 26.137 24 3.73 13 3.73 1117.6 80.96 0.0764
800 405.16 26.137 18 3.73 19 3.73 1117.6 90.3 0.0782
850 430.9 26.949 33 3.85 4 3.85 1187.4 71.17 0.0693
850 430.9 26.949 30 3.85 7 3.85 1187.4 77.4 0.0701
850 430.9 26.949 24 3.85 13 3.85 1187.4 85.41 0.0718
850 430.9 26.949 18 3.85 19 3.85 1187.4 95.19 0.0736
900 456.26 27.737 33 3.96 4 3.96 1257.3 75.62 0.0655
900 456.26 27.737 30 3.96 7 3.96 1257.3 81.85 0.0663
900 456.26 27.737 24 3.96 13 3.96 1257.3 90.3 0.0678
900 456.26 27.737 18 3.96 19 3.96 1257.3 99.64 0.0695
950 481.16 28.473 33 4.07 4 4.07 1327.1 79.62 0.0621
950 481.16 28.473 30 4.07 7 4.07 1327.1 86.3 0.0628
Total Cross
Selection
Overall
Diameter
Stranding- Number and Diameter Mass Rated
Strength
20ºC DC Resistance
Outer Strands-EC-H19
Diameter
Reinforced Strands-6201-T81
kcmil or AWG   mm2    mm   No.   mm  No.  mm   kg/km    kN  Ω/km
950 481.16 28.473 24 4.07 13 4.07 1327.1 95.19 0.0643
950 481.16 28.473 18 4.07 19 4.07 1327.1 106.31 0.0659
1000 506.64 29.235 33 4.18 4 4.18 1396.9 84.07 0.0590
1000 506.64 29.235 30 4.18 7 4.18 1396.9 90.74 0.0597
1000 506.64 29.235 24 4.18 13 4.18 1396.9 100.53 0.0611
1000 506.64 29.235 18 4.18 19 4.18 1396.9 112.1 0.0626
1000 506.39 29.261 54 3.25 7 3.25 1396.9 87.63 0.0591
1000 506.39 29.261 48 3.25 13 3.25 1396.9 93.86 0.0599
1000 506.39 29.261 42 3.25 19 3.25 1396.9 101.86 0.0608
1000 506.39 29.261 33 3.25 28 3.25 1396.9 122.33 0.0621
1100 557.22 30.658 33 4.38 4 4.38 1537.3 92.08 0.0536
1100 557.22 30.658 30 4.38 7 4.38 1537.3 100.08 0.0543
1100 557.22 30.658 24 4.38 13 4.38 1537.3 110.32 0.0555
1100 557.22 30.658 18 4.38 19 4.38 1537.3 123.22 0.0569
1100 557.48 30.709 54 3.41 7 3.41 1537.3 96.08 0.0537
1100 557.48 30.709 48 3.41 13 3.41 1537.3 101.86 0.0545
1100 557.48 30.709 42 3.41 19 3.41 1537.3 110.32 0.0552
1100 557.48 30.709 33 3.41 28 3.41 1537.3 118.32 0.0564
1200 608.13 32.029 33 4.58 4 4.58 1677.2 100.53 0.0491
1200 608.13 32.029 30 4.58 7 4.58 1677.2 108.98 0.0497
1200 608.13 32.029 24 4.58 13 4.58 1677.2 120.55 0.0509
1200 608.13 32.029 18 4.58 19 4.58 1677.2 134.34 0.0521
1200 608.39 32.08 54 3.56 7 3.56 1677.2 102.75 0.0492
1200 608.39 32.08 48 3.56 13 3.56 1677.2 109.87 0.0499
1200 608.39 32.08 42 3.56 19 3.56 1677.2 118.77 0.0506
1200 608.39 32.08 33 3.56 28 3.56 1677.2 128.11 0.0517
1250 633.35 32.69 33 4.67 4 4.67 1745.6 104.98 0.0472
1250 633.35 32.69 30 4.67 7 4.67 1745.6 113.87 0.0477
1250 633.35 32.69 24 4.67 13 4.67 1745.6 125.44 0.0489
1250 633.35 32.69 18 4.67 19 4.67 1745.6 140.12 0.0500
1250 632.9 32.715 54 3.64 7 3.64 1745.6 107.2 0.0473
1250 632.9 32.715 48 3.64 13 3.64 1745.6 114.32 0.0479
1250 632.9 32.715 42 3.64 19 3.64 1745.6 123.66 0.0486
Total Cross
Selection
Overall
Diameter
Stranding- Number and Diameter Mass Rated
Strength
20ºC DC Resistance
Outer Strands-EC-H19
Diameter
Reinforced Strands-6201-T81
kcmil or AWG   mm2    mm   No.   mm  No.  mm   kg/km    kN  Ω/km
1250 632.9 32.715 33 3.64 28 3.64 1745.6 133.45 0.0497
1300 658.39 33.325 33 4.76 4 4.76 1815.6 108.98 0.0454
1300 658.39 33.325 30 4.76 7 4.76 1815.6 118.32 0.0459
1300 658.39 33.325 24 4.76 13 4.76 1815.6 130.33 0.0470
1300 658.39 33.325 18 4.76 19 4.76 1815.6 145.46 0.0482
1300 658.84 33.376 54 3.71 7 3.71 1815.6 111.65 0.0454
1300 658.84 33.376 48 3.71 13 3.71 1815.6 119.21 0.0461
1300 658.84 33.376 42 3.71 19 3.71 1815.6 128.55 0.0467
1300 658.84 33.376 33 3.71 28 3.71 1815.6 138.78 0.0478
1400 709.42 34.646 54 3.85 7 3.85 1955.4 117.88 0.0422
1400 709.42 34.646 48 3.85 13 3.85 1955.4 126.33 0.0428
1400 709.42 34.646 42 3.85 19 3.85 1955.4 137.01 0.0434
1400 709.42 34.646 33 3.85 28 3.85 1955.4 148.13 0.0444
1500 759.93 35.389 54 3.98 7 3.98 2095.3 126.33 0.0394
1500 759.93 35.839 48 3.98 13 3.98 2095.3 135.23 0.0399
1500 759.93 35.839 42 3.98 19 3.98 2095.3 146.79 0.0405
1500 759.93 35.839 33 3.98 28 3.98 2095.3 158.8 0.0414
1600 811.16 37.033 54 4.12 7 4.12 2235.2 135.23 0.0369
1600 811.16 37.033 48 4.12 13 4.12 2235.2 144.57 0.0374
1600 811.16 37.033 42 4.12 19 4.12 2235.2 156.58 0.0380
1600 811.16 37.033 33 4.12 28 4.12 2235.2 169.48 0.0388
1700 860.97 38.151 54 4.24 7 4.24 2375.1 143.23 0.0348
1700 860.97 38.151 48 4.24 13 4.24 2375.1 153.46 0.0353
1700 860.97 38.151 42 4.24 19 4.24 2375.1 166.36 0.0358
1700 860.97 38.151 33 4.24 28 4.24 2375.1 180.15 0.0365
1750 887.1 38.735 54 4.30 7 4.30 2445.1 147.68 0.0337
1750 887.1 38.735 48 4.30 13 4.30 2445.1 157.91 0.0342
1750 887.1 38.735 42 4.30 19 4.30 2445.1 171.26 0.0347
1750 887.1 38.735 33 4.30 28 4.30 2445.1 185.49 0.0355
1800 912.26 39.268 54 4.36 7 4.36 2515 151.68 0.0328
1800 912.26 39.268 48 4.36 13 4.36 2515 162.36 0.0333
1800 912.26 39.268 42 4.36 19 4.36 2515 176.15 0.0337
1800 912.26 39.268 33 4.36 28 4.36 2515 190.83 0.0345
Total Cross
Selection
Overall
Diameter
Stranding- Number and Diameter Mass(Total Conductor) Rated
Strength
20ºC DC Resistance
Outer Strands-EC-H19
Diameter
Reinforced Strands-6201-T81
kcmil or AWG   mm2    mm   No.   mm  No.  mm   kg/km    kN  Ω/km
1900 962.84 40.361 54 4.48 7 4.48 2654.9 160.14 0.0311
1900 962.84 40.361 48 4.48 13 4.48 2654.9 171.7 0.0315
1900 962.84 40.361 42 4.48 19 4.48 2654.9 185.94 0.0320
1900 962.84 40.361 33 4.48 28 4.48 2654.9 201.5 0.0327
2000 1013.74 41.402 54 4.60 7 4.60 2793.3 168.59 0.0295
2000 1013.74 41.402 48 4.60 13 4.60 2793.3 180.6 0.0299
2000 1013.74 41.402 42 4.60 19 4.60 2793.3 195.72 0.0304
2000 1013.74 41.402 33 4.60 28 4.60 2793.3 211.74 0.0310
2000 1012.9 41.402 72 3.76 19 3.76 2793.3 182.38 0.0302
2000 1012.9 41.402 63 3.76 28 3.76 2793.3 193.05 0.0306
2000 1012.9 41.402 54 3.76 37 3.76 2793.3 207.29 0.0311
2250 1139.35 43.917 72 3.99 19 3.99 3174.3 202.39 0.0268
2250 1139.35 43.917 63 3.99 28 3.99 3174.3 214.85 0.0272
2250 1139.35 43.917 54 3.99 37 3.99 3174.3 230.86 0.0276
2500 1265.8 46.304 72 4.21 19 4.21 3526.9 225.08 0.0241
2500 1265.8 46.304 63 4.21 28 4.21 3526.9 238.87 0.0245
2500 1265.8 46.304 54 4.21 37 4.21 3526.9 256.66 0.0249
2750 1392.9 48.565 72 4.42 19 4.42 3879.6 247.32 0.0219
2750 1392.9 48.565 63 4.42 28 4.42 3879.6 262.45 0.0223
2750 1392.9 48.565 54 4.42 37 4.42 3879.6 282.46 0.0226
3000 1520.64 50.749 72 4.61 19 4.61 4232.3 270.01 0.0201
3000 1520.64 50.749 63 4.61 28 4.61 4232.3 286.91 0.0204
3000 1520.64 50.749 54 4.61 37 4.61 4232.3 308.26 0.0207
2000 1013.74 41.402 48 4.60 13 4.60 2793.3 180.6 0.0299
2000 1013.74 41.402 42 4.60 19 4.60 2793.3 195.72 0.0304
2000 1013.74 41.402 33 4.60 28 4.60 2793.3 211.74 0.0310
2000 1012.9 41.402 72 3.76 19 3.76 2793.3 182.38 0.0302
2000 1012.9 41.402 63 3.76 28 3.76 2793.3 193.05 0.0306
2000 1012.9 41.402 54 3.76 37 3.76 2793.3 207.29 0.0311
2250 1139.35 43.917 72 3.99 19 3.99 3174.3 202.39 0.0268
2250 1139.35 43.917 63 3.99 28 3.99 3174.3 214.85 0.0272
2250 1139.35 43.917 54 3.99 37 3.99 3174.3 230.86 0.0276
2500 1265.8 46.304 72 4.21 19 4.21 3526.9 225.08 0.0241
Total Cross
Selection
Overall
Diameter
Stranding- Number and Diameter Mass Rated
Strength
20ºC DC Resistance
Outer Strands-EC-H19
Diameter
Reinforced Strands-6201-T81
kcmil or AWG   mm2    mm   No.   mm  No.  mm   kg/km    kN  Ω/km
2500 1265.8 46.304 63 4.21 28 4.21 3526.9 238.87 0.0245
2500 1265.8 46.304 54 4.21 37 4.21 3526.9 256.66 0.0249
2750 1392.9 48.565 72 4.42 19 4.42 3879.6 247.32 0.0219
2750 1392.9 48.565 63 4.42 28 4.42 3879.6 262.45 0.0223
2750 1392.9 48.565 54 4.42 37 4.42 3879.6 282.46 0.0226
3000 1520.64 50.749 72 4.61 19 4.61 4232.3 270.01 0.0201
3000 1520.64 50.749 63 4.61 28 4.61 4232.3 286.91 0.0204
3000 1520.64 50.749 54 4.61 37 4.61 4232.3 308.26 0.0207
2500 1265.8 46.304 63 4.21 28 4.21 3526.9 238.87 0.0245
2500 1265.8 46.304 54 4.21 37 4.21 3526.9 256.66 0.0249
2750 1392.9 48.565 72 4.42 19 4.42 3879.6 247.32 0.0219
2750 1392.9 48.565 63 4.42 28 4.42 3879.6 262.45 0.0223
2750 1392.9 48.565 54 4.42 37 4.42 3879.6 282.46 0.0226
3000 1520.64 50.749 72 4.61 19 4.61 4232.3 270.01 0.0201
3000 1520.64 50.749 63 4.61 28 4.61 4232.3 286.91 0.0204
3000 1520.64 50.749 54 4.61 37 4.61 4232.3 308.26 0.0207

Packing and loading containers pictures:
Bare Aluminum Conductor Alloy Reinforced (ACAR) CableBare Aluminum Conductor Alloy Reinforced (ACAR) Cable
Bare Aluminum Conductor Alloy Reinforced (ACAR) CableBare Aluminum Conductor Alloy Reinforced (ACAR) CableBare Aluminum Conductor Alloy Reinforced (ACAR) Cable
* We can design and produce ACAR according to client's requirement. Any requirement, feel free to contact us for best offer!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier